Low consumption WinPACK HE-A

TCAEY-THAEY 2110÷4340

Cooling capacity: 91.6÷345 kW

Heating capacity: 110.5÷357 kW

WEBCODE: WKE11

Product benefits

  • Class A chillers and heat pumps
  • Standard electronic expansion valve
  • Multipurpose for systems with 2 pipes + DHW (with optional RC100)
  • Integrated MASTER/SLAVE control
IntCert5 GreenLine_logo AdesivoAfP_logo
  • SoloRaffr_logo
  • PdC_logo
  • Install_EST_logo
  • R410A_logo
  • IntCert2
  • CE_logo
  • Eurovent_logo
  • Bureau_Veritas_logo

Water chillers and packaged reversible air-cooled heat pumps with axial fans. Range with scroll hermetic compressors and R410A refrigerant.



Construction features

• Compressor: scroll type, rotary, hermetic complete with thermal protection and casing heater.
• 2, 3 or 4 capacity steps with high efficiency at partial loads.
Water side heat exchanger: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Air side heat exchanger: featuring micro-channels or finned coil with copper pipes and aluminium fins depending on models/sizes.
• Fan: external rotor axial type electric fans with internal thermal protection, accident protection grilles.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: load bearing structure made of galvanised and painted steel plate coated with polyester powders.
• The unit is also complete with:
- compressor and fan circuit breaker switches;
- display of cooling circuit high and low pressure;
- electronic expansion valve;
- Master/Slave control up to 4 units in parallel;
- clock board.


Versions

• T - High efficiency version with oversized condensing section (TCAETY-THAETY).
• Q - Super-silenced version complete with soundproofing compressor technical compartment, super-reduced speed fans and oversized condensing section (TCAEQY-THAEQY).


Models

• TCAETY: high efficiency unit designed for cooling only.
• TCAEQY: super silenced unit designed for cooling only.
• THAETY: heat pump unit.
• THAEQY: super silenced heat pump unit.


Factory fitted accessories

• Shell and tube evaporator.
• PUMP with single or double electric pump, including an automatic pump in standby. The pumps are available in the low or high head versions.
• TANK&PUMP with integrated buffer tank from 300 to 700 litres (depending on models) and single or double electric pump, complete with expansion tank, air vent valves, safety valve, and water side pressure gauge.
• VPF control.
• Desuperheater.
• 100% heat recovery unit
• -10°C condensing control.
• -15°C condensing control with fans with EC motor (standard with Q versions).
• Condensing control with over-pressure fans.
• Power factor correction capacitors (cosφ > 0.94).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameter measuring device.
• Optimised energy efficiency.
• Soft starter.
• Soundproofed compressor box or technical compartment soundproofing.
• Compressor soundproof enclosures.
• Cooling circuit delivery and intake valves.
• Refrigerant leak detector.
• Cooling circuit high and low pressure gauges.
• Double safety valves.
• Metal filters or coil protection nets.
• Micro-channel coils with E-coating treatment.
• Copper/copper or copper/pre-painted aluminium coils.
• Control of min/max power supply voltage.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Evaporator antifreeze heater, electrical panel, buffer tank, electric pumps and heat exchangers for heat recovery if applicable.
• Buffer tank integrative heaters
• Low temperature water production.
• Interfaces for serial communication with other devices.
• Anti-vibration mounts.


Separately supplied accessories

• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.


TCAETY-TCAEQY MODEL
Nominal cooling capacity kW
Nominal cooling capacity kW
E.E.R.
E.E.R.
Absorbed power kW
Absorbed power kW
THAETY-THAEQY MODEL
Nominal heating capacity kW
Nominal heating capacity kW
C.O.P.
C.O.P.
Nominal cooling capacity kW
Nominal cooling capacity kW
Absorbed power kW
Absorbed power kW
TCAETY-TCAEQY-THAETY-THAEQY MODEL
TCAETY sound pressure dB(A)
THAETY sound pressure dB(A)
TCAEQY-THAEQY sound pressure dB(A)
TCAETY sound power dB(A)
THAETY sound power dB(A)
TCAEQY-THAEQY sound power dB(A)
Scroll/step compressor no.
Circuits no.
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHTS
L - Width mm
H - Height mm
P - Depth mm
TCAETY weight kg
TCAEQY weight kg
THAETY weight kg
THAEQY weight kg
SEASONAL ENERGY PERFORMANCE
TCAETY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW
SEER  (EN 14825)
ηs,c %
TCAEQY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW
SEER  (EN 14825)
ηs,c %
THAETY MODEL SEASONAL PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW
SCOP (EN 14825)
ηs %
THAEQY MODEL SEASONAL PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW
SCOP (EN 14825)
ηs %
2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
110,5 121,5 138,4 156,4 175,4 200,3 223,2 241,3 276,3 309,1 345,1
100,6 108,6 126,5 140,5 155,5 181,4 199,4 218,4 251,4 280,2 318,2
3,13 3,1 3,13 3,11 3,1 3,11 3,1 3,1 3,1 3,1 3,1
2,73 2,6 2,69 2,65 2,6 2,64 2,61 2,56 2,68 2,62 2,63
35,3 39,2 44,2 50,3 56,6 64,4 72 77,8 88,8 99,7 111,3
36,8 41,8 47 53 59,8 68,7 76,4 85 93,8 106,9 121
2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
114,5 124,5 141,6 161,6 181,7 204,8 233,9 249,8 282,8 321 357
110,5 118,5 136,5 153,6 171,6 194,7 221,8 236,7 266,7 301 341,9
3,22 3,22 3,21 3,22 3,23 3,22 3,21 3,2 3,2 3,2 3,2
3,28 3,29 3,27 3,26 3,26 3,23 3,26 3,12 3,11 2,95 3,08
101,6 112,6 126,5 145,4 161,4 186,3 209,3 231,3 263,3 301,1 334,1
91,6 100,6 118,6 130,6 144,5 169,5 187,4 206,5 238,4 270,3 302,3
35,6 38,7 44,1 50,2 56,3 63,6 72,9 78,1 88,4 100,3 111,6
33,7 36 41,7 47,1 52,6 60,3 68 75,9 85,8 102 111
2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
55 56 57 57 58 59 59 58 60 60 62
53 54 55 55 56 57 57 58 60 60 62
47 47 48 48 49 50 50 51 53 53 54
87 88 89 89 90 91 91 90 92 92 94
85 86 87 87 88 89 89 90 92 92 94
79 79 80 80 81 82 82 83 85 85 86
2/3 2/3 2/2 2/3 2/2 2/3 2/2 4/4 4/4 4/4 4/4
1 1 1 1 1 1 1 2 2 2 2
400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
3600 3600 3600 3600 4550 4550 4550 4800 4800 5300 5300
2440 2440 2440 2440 2440 2440 2440 2030 2030 2030 2030
1350 1350 1350 1350 1350 1350 1350 2090 2090 2090 2090
1090 1100 1110 1130 1280 1300 1320 2290 2390 2520 2640
1250 1260 1270 1290 1440 1460 1480 2420 2520 2650 2770
1380 1410 1420 1500 1670 1690 1780 2470 2570 2720 2840
1420 1450 1460 1540 1710 1730 1820 2600 2700 2850 2970
2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
110,5 121,5 138,4 156,3 175,3 200,2 223,1 241,3 276,2 309,1 345
4,21 4,26 4,1 4,22 4,27 4,21 4,24 4,29 4,3 4,29 4,3
165 167 161 166 168 165 167 169 169 168 169
100,6 108,6 126,5 140,5 155,4 181,3 199,3 218,4 251,4 280,2 318,2
4,13 3,99 4,01 4,07 3,95 4,08 4 4,09 4,17 4,17 4,13
162 157 157 160 155 160 157 160 164 164 162
96 104 118 135 150 173 201 211 242 273 302
3,53 3,51 3,75 3,49 3,76 3,39 3,57 3,64 3,62 3,64 3,63
138 138 147 137 148 133 140 142 142 143 142
91 98 113 127 141 165 190 199 227 254 288
3,62 3,61 3,84 3,59 3,87 3,53 3,65 3,56 3,54 3,37 3,52
142 141 151 141 152 138 143 139 139 132 138

Data at the following conditions:

Air: 35°C - Water: 12/7°C.

Air: 7°C, D.B. 6°C W.B.- Water: 40/45°C.

In open field (Q = 2) at 10 m from the unit.

Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.

Weight referred to the unit without load and not accessorised.

TCAEQY-THAEQY super-silenced versions.

Performance according to EN 14511:2013.

Low temperature application (7°C)

Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)

In Average climatic conditions, low temperature application (35°C)

Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/213 and No.813/2013)

References

28 November 2018

Domar SpA

ITALY