Ductable terminals

YARDY-HP

Cooling capacity: 7.2÷19.8 kW

Heating capacity: 9.9÷29.6 kW

WEBCODE: YAHP1 ACMEC controls: ACREG

Product benefits

  • Air'Suite biocide filter for healthier and cleaner air in indoor environments
  • New touch controls
  • Horizontal and vertical installation
  • Pan removable from below for cleaning
  • Hydraulic and electric connections on the same side.
  • Set up with 3, 4, 5-row coil
Garanzia5_logoFR
  • Canalizabile_logo
  • CE_logo

Ductable terminals for recessed horizontal or vertical installation.



Construction features

• Structure: self-supporting, in galvanised sheet steel for horizontal installation in a false ceiling or vertical recessed wall installation, complete with a natural condensate drain pan, flanges to fit to the inlet/delivery duct. Pan is removable from below.
Filter supplied separately from the unit.
• Finned coil heat exchanger, removable from below, with connections on the left, reversible to the right directly on site.
• Electrical connection box: on the left, on the same side as the hydraulic connections, reversible to the right directly on site.
• Double intake centrifugal fan with directly coupled 3-speed motor.
Fan unit is removable from below.


Versions

• CXP - Recessed unit for horizontal or vertical installation (with lower return to upper delivery).
Number of rows
• 3 Rows - Unit with 3-row coil; for recessed horizontal/vertical installation.
• 4 Rows - Unit with 4-row coil; for recessed horizontal/vertical installation.
• 5 Rows - Unit with 5-row coil (only models 250, 300); for recessed horizontal/vertical installation.


Construction set-ups

Type of unit
2T - Single main coil
4T - Double main coil and additional


ACCESSORIES

➔❖ Additional water heating coil (1 row) for [4T-KBAA] 4-pipe systems - only for 3R units with a 3-row coil.
➔ External plenum with additional water heating coil for 4-pipe systems [PBAB].
➔❖2-way ON/OFF electrovalves for 2 and 4-pipe systems.

➔❖3-way ON/OFF electrovalves for 2 and 4-pipe systems.
➔❖ Auxiliary condensate drain pan.
➔ Frame with filter that can be extracted in any direction (G1 or G3).
➔ Frame with Air'Suite biocide filter (G2) that can be extracted in any direction.
➔ Straight delivery and inlet fitting.
➔ 90° delivery and inlet fitting.
➔ Flange for duct connection.
➔ Anti-vibration fitting for connection to the inlet/delivery duct.
➔ Panel with round nozzles to be connected to the delivery/inlet fittings.


CONTROLS

STANDARD controls
For wall mounting installation
➔ Panel with speed and summer/winter switch.
➔ Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve control and electrical resistance.
➔ Electronic panel with automatic summer/winter switching for 2-pipe systems.
➔ Electronic panel with automatic summer/winter switching and automatic speed adjustment for 2-pipe systems with electrical resistance or 4-pipe systems.
➔ Air probe with remote control option.
➔ Interface board to control up to 4 fan coils (models 100-150-200 only, for on board installation).


Advanced LIT-TOUCH controls

➔ Wired LIT-Touch control panel in glossy black or pearl white for wall mounting installation.
➔ Wall mounted LIT-Touch remote control and receiver with air temperature probe and operation LED.
For on board installation
➔❖ LIT-Touch electronic control for 2-pipe systems, with 2 pipes with electrical resistance or 4 pipes, complete with minimum water temperature probe, ON/OFF valve control and integrated master/slave function up to a total of 15 units.
➔❖ Additional board with 2 digital outputs that can be configured.
➔❖ On board air temperature probe.
➔❖ RS485 serial board for serial communication with other devices (Modbus RTU protocol).

Key: ❖ Factory fitted
➔ Supplied separately

YARDY HP CXP
Total cooling capacity [EN1397] kW
kW
kW
Heating capacity (45°C) [EN1397] kW
kW
kW
Heating capacity (50°C) kW
kW
kW
Total cooling capacity [EN1397] kW
kW
kW
Heating capacity (45°C) [EN1397] kW
kW
kW
Heating capacity (50°C) kW
kW
kW
Total cooling capacity [EN1397] kW
kW
kW
Heating capacity (45°C) [EN1397] kW
kW
kW
Heating capacity (50°C) kW
kW
kW
Heating capacity of additional coil (70°C) kW
Heating capacity of additional coil (65°C) [EN1397] kW
Heating capacity of additional coil (70°C) [EN1397] kW
Heating capacity of additional coil (65°C) [EN1397] kW
Air flow rate/Speed static pressure (3R) m³/h / Pa
m³/h / Pa
m³/h / Pa
Delivery sound power (3R) dB(A)
dB(A)
dB(A)
Speed sound pressure (3R) dB(A)
dB(A)
dB(A)
Nominal spd absorbed power MAX W
W
W
Maximum absorbed power (0 Pa) W
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHTS
L - Width mm
H - Height mm
P - YARDY HP Depth mm
P - PBAB Depth mm
YARDY HP Weight kg
100 150 200 250 300
6,96 8,13 9,75 12,85 14,42
6,45 6,49 7,19 9,32 11,15
5,33 6,19 6,43 6,87 9,82
8,38 10,23 12,58 17,03 19,51
7,61 7,85 8,99 11,62 14,71
6,08 7,34 7,77 8,09 12,49
9,85 12,09 14,85 20,13 23,11
9 9 10,41 13,64 17,01
7,27 8,53 9,11 9,64 14,6
8,22 9,28 11,04 15,88 18
7,53 8,09 8,95 11,79 14,31
6,31 7,61 8,14 8,36 12,52
9,32 10,93 13,34 19,59 22,62
8,35 9,09 10,33 13,9 17,73
6,83 8,39 9,1 9,27 14,85
11,01 12,88 15,73 23,36 27,12
9,93 10,58 12,11 16,55 20,9
8,18 9,87 10,79 11,15 17,67
- - - 18,04 19,75
- - - 12,78 16,32
- - - 8,91 14,04
- - - 21,83 24,62
- - - 14,42 18,69
- - - 9,37 16,19
- - - 26,23 29,62
- - - 17,26 22,23
- - - 11,47 19,24
6,89 7,03 9,73 11,12 12,11
6,11 6,23 8,63 9,88 10,76
13,1 14,39 16,78 30,41 33,57
11,61 12,74 14,87 26,98 29,77
1.552 / 60 1.840 / 60 2.339 / 60 3.312 / 60 3.875 / 60
1.370 / 50 1.620 / 50 1.717 / 50 2.189 / 50 3.075 / 50
1.013 / 35 1.432 / 35 1.414 / 35 1.329 / 35 2.415 / 35
61 62 62 63 68
59 61 60 59 64
56 59 57 55 61
47 48 48 49 54
45 47 46 45 50
42 45 43 41 47
200 245 380 680 800
190 230 330 670 750
- - - 660 750
280 300 500 850 900
230-1-50 230-1-50 230-1-50 230-1-50 230-1-50
100 150 200 250 300
1295 1295 1295 1295 1295
250 250 285 335 335
555 555 670 720 720
200 200 200 200 200
38 38 46 57 57

Data at the following conditions:

Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C.

Air: 20°C - Water: 45/40°C.

Air: 20°C - Water: 50°C, flow rate as in cooling.

Air: 20°C - Water: 70/60°C.

Air: 20°C - Water: 65/55°C.

3 row coil (3R) without filter.

With G3 filter at the conditions specified in point 6 according to EN16583

At 2 m from the air outflow point with directionality factor 2 and G3 filter.