Ducted fan coils with EC motor

YARDY-ID2

Cooling capacity: 3.0÷6.3 kW

Heating capacity: 3.9÷8.7 kW

WEBCODE: YAID2 ACMEC controls: ACREG

Product benefits

  • Air'Suite biocide filter for healthier and cleaner air in indoor environments
  • New touch controls
  • Enhanced performance with 4-row coil
  • Consumption reduced by 50% with EC motor
  • Continuous fan speed regulation
  • Horizontal and vertical installation
Inverter_logo GreenLine_logo Garanzia5_logoFR
  • Canalizabile_logo
  • IntCert1
  • CE_logo
  • Eurovent_logo

Ducted fan coils for recessed horizontal or vertical installation.



Construction features

• Heat exchanger: with finned coil with left side connections reversible to the right.
• Centrifugal fan: with an inverter controlled electronic brushless motor and continuous speed adjustment.
• Structure: made of galvanised sheet steel complete with a natural condensate drain pan and regenerable filter.


Versions

• CXP - Recessed unit for horizontal or vertical installation (with lower return and upper delivery).


Construction set-ups

Type of unit
2T - Single main coil
4T - Double main coil and additional


ACCESSORIES

➔❖ Additional water heating coil for 4-pipe systems.
➔❖ Electrical resistance.
➔❖ 2 -way ON/OFF electrovalves for 2 and 4-pipe systems.
➔❖ 3 -way ON/OFF electrovalves for 2 and 4-pipe systems.
➔❖ 4-way ON/OFF electrovalves for 4-pipe systems with single main coil.
➔❖ Auxiliary condensate drain pan.
➔❖ Air'Suite biocide filter.
❖ Electrical box for connection terminal block.
❖ Air inlet flange: Ø10cm or Ø12cm.
➔ Flanged frame for connection to intake or delivery duct.

➔ Frame with Air'Suite biocide filter (G2) that can be extracted in any direction.
➔ Delivery straight fitting.
➔ 90° delivery and inlet fitting.
➔ Telescopic outlet/inlet fitting.
➔ Inlet grille with filter.
➔ Delivery grille.
➔ Formwork for recessed wall or false ceiling installation.
➔ Aesthetic panel for formwork, with air inlet grille for wall mounting or ceiling installation.
➔ Delivery nozzle made of aluminium, with a double row of adjustable fins.
➔ Anti-vibration fitting for delivery/inlet duct connection.
➔ Intake/outlet plenum with round nozzles.


CONTROLS

STANDARD controls
For wall mounting installation
➔ Electronic panel with display and RS485 serial interface, semi-recessed in wall.


Advanced LIT-TOUCH controls

➔ Wired LIT-Touch control panel in glossy black or pearl white for wall mounting installation.
➔ Wall mounted LIT-Touch remote control and receiver with air temperature probe and operation LED.
For on board installation
➔❖ LIT-Touch electronic control for 2-pipe systems, with 2 pipes with electrical resistance or 4 pipes, complete with minimum water temperature probe, ON/OFF valve control and integrated master/slave function up to a total of 15 units.
➔❖ Additional board with 2 digital outputs that can be configured.
➔❖ On board air temperature probe.
➔❖ RS485 serial board for serial communication with other devices (Modbus RTU protocol).

Key: ❖ Factory fitted
➔ Supplied separately

YARDY-ID2 CXP
Total cooling capacity [EN1397] kW
kW
kW
Heating capacity (45°C) [EN1397] kW
kW
kW
Heating capacity (50°C) kW
kW
kW
Heating capacity (70°C) [EN1397] kW
kW
kW
Heating capacity of additional coil (65°C) [EN1397] kW
kW
kW
Heating capacity of additional coil (70°C) [EN1397] kW
kW
kW
Available static Air flow rate / Pressure m³/h / Pa
m³/h / Pa
m³/h / Pa
Delivery sound power dB(A)
dB(A)
dB(A)
Delivery sound pressure dB(A)
dB(A)
dB(A)
Absorbed power W
W
W
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHTS
L - Width mm
H - Height mm
P - Depth mm
Weight kg
40 48 60 74 80 88
3,01 E 3,28 E 4,12 E 4,58 E 5,88 E 6,26 E
2,7 E 2,95 E 3,5 E 4,42 E 5,32 E 5,7 E
1,19 E 1,28 E 1,58 E 1,72 E 2,03 E 2,29 E
3,29 E 3,35 E 4,73 E 4,77 E 7,37 E 7,48 E
2,93 E 2,97 E 4,53 E 4,48 E 6,6 E 6,71 E
1,16 E 1,18 E 1,58 E 1,6 E 2,5 E 2,51 E
3,86 3,94 5,52 5,63 8,55 8,72
3,44 3,51 5,23 5,33 7,69 7,84
1,39 1,42 1,9 1,94 2,92 2,98
6,55 6,66 9,44 9,62 14,71 14,93
5,84 5,92 9,04 9,1 13,21 13,42
2,35 2,39 3,24 3,27 5,1 5,13
2,75 E 2,63 E 4,17 E 4,32 E 5,7 E 5,42 E
2,51 E 2,41 E 4 E 3,7 E 5,1 E 5,02 E
1,28 E 1,22 E 1,91 E 1,91 E 2,42 E 2,3 E
3,19 3,03 4,71 4,89 6,46 6,14
2,92 2,78 4,51 4,18 5,78 5,69
1,48 1,41 2,21 2,2 2,79 2,65
469 / 64 E 469 / 64 E 737 / 56 E 737 / 56 E 1010 / 65 E 949 / 64 E
410 / 50 E 410 / 50 E 691 / 50 E 691 / 50 E 866 / 50 E 831 / 50 E
150 / 8 E 150 / 8 E 214 / 6 E 214 / 6 E 284 / 7 E 284 / 7 E
56 E 56 E 57 E 57 E 58 E 58 E
52 E 52 E 56 E 56 E 57 E 57 E
30 E 30 E 30 E 30 E 30 E 30 E
47 47 48 48 49 49
43 43 47 47 48 48
21 21 21 21 21 21
69 E 72 E 100 E 105 E 140 E 140 E
60 E 63 E 80 E 84 E 100 E 100 E
8 E 8 E 8 E 8 E 13 E 13 E
230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50
40 48 60 74 80 88
950 950 1250 1250 1250 1250
545 545 545 545 545 545
212 212 212 212 212 212
25,5 26,5 34,5 35,5 36,5 37,5

Data at the following conditions:

Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C.

Air: 20°C - Water: 45/40°C.

Air: 20°C - Water: 50°C, flow rate as in cooling.

Air: 20°C - Water: 70/60°C.

Air: 20°C - Water: 65/55°C.

According to EN16583

For room volume equal to 100 m³ and reverberation time = 0.5 sec.

E

Eurovent certified performance.

Performance refers to the motor’s input signal: 10V - 7V - 2V at MAX - MED - MIN speed.

Yardy ID2 48 - 74 - 88 with oversized 4-row coil.

For the selection with Air’Suite filter please refer to UP-TO-DATE selection software.