Fan coils with EC motor

YARDY-I EV3

Cooling capacity: 1.9÷8.4 kW

Heating capacity: 2.5÷11.8 kW

WEBCODE: YARI3 ACMEC controls: ACREG

Product benefits

  • New white RAL 9003 for versions with cabinet
  • New touch controls
  • Air'Suite biocide filter for healthier and cleaner air in indoor environments
  • Enhanced performance with 4-row coil
  • Consumption reduced by 50% with EC motor
  • Continuous fan speed regulation
Inverter_logo GreenLine_logo Garanzia5_logoFR
  • IntCert1
  • CE_logo
  • Eurovent_logo

Floor and ceiling fan coil units with cabinet for recessed wall or false ceiling installation.



Construction features

• Heat exchanger: with finned coil with left side connections reversible to the right.
• Centrifugal fan with an inverter controlled electronic brushless motor and continuous speed adjustment.
• Cabinet version structure: covering cabinet in pre-painted sheet steel, RAL9003, complete with a regenerable filter, ABS polymer grilles and a natural condensate drain pan.
• Recessed version structure: in galvanised sheet steel, complete with a natural condensate drain pan and regenerable filter.


Versions

• MVP - Vertical unit with cabinet equipped with lower air inlet and upper delivery for wall mounting installation or with feet on the ground.
• MVT - Vertical unit with cabinet equipped with front air inlet and upper delivery for floor installation.
• MXP - Horizontal/vertical unit with cabinet, equipped with lower air inlet and upper delivery, for ceiling installation, wall mounted or with feet on the ground.
• MXT - Horizontal/vertical unit with cabinet, equipped with front air inlet and upper delivery, for ceiling or floor installation.
• IVP - Recessed vertical unit equipped with lower air inlet and upper delivery for wall mounting installation.
• IVF - Recessed vertical unit equipped with lower air inlet and front delivery for wall mounting installation.
• IXP - Horizontal/vertical unit equipped with lower air inlet and upper delivery for false ceiling or recessed wall installation.


Construction set-ups

Type of unit
2T - Single main coil.
4T - Double main coil and additional.


ACCESSORIES

➔❖ Additional water heating coil for 4-pipe systems.
➔❖ Electrical resistance.
➔❖ 2 -way ON/OFF electrovalves for 2 and 4-pipe systems.
➔❖ 3 -way ON/OFF electrovalves for 2 and 4-pipe systems.
➔❖ 4-way ON/OFF electrovalves for 4-pipe systems with single main coil.
➔❖ Auxiliary condensate drain pan.
➔❖ Air'Suite biocide filter.
❖ Electrical box for connection terminal block.
❖ Air inlet flange: Ø10cm or Ø12cm.
➔ Manual damper.
➔ Motorised damper.
➔ Back in view.
➔ Rear closing panel.
➔ Rear closing panel with grille and filter.
➔ Support feet with pipe cover.
➔ Flanged frame for duct connection.
➔ Frame with Air'Suite biocide filter (G2) that can be extracted in any direction.
➔ Delivery straight fitting.
➔ 90° delivery and inlet fitting.
➔ Telescopic outlet/inlet fitting.
➔ Inlet grille with filter.
➔ Delivery grille.
➔ Formwork for recessed wall or false ceiling installation.
➔ Aesthetic panel for wall mounted formwork, with air delivery and return grille.
➔ Aesthetic panel for formwork, with air inlet grille.
➔ Delivery nozzle made of aluminium, with a double row of adjustable fins.
➔ Anti-vibration fitting for delivery/inlet duct connection.
➔ Intake/outlet plenum with round nozzles.


CONTROLS

STANDARD controls
For wall mounting installation
➔ Electronic panel with display and RS485 serial interface, semi-recessed in wall.


Advanced LIT-TOUCH controls

➔ Wired LIT-Touch control panel in glossy black or pearl white for wall mounting installation.
➔ Wall mounted LIT-Touch remote control and receiver with air temperature probe and operation LED.
➔❖ LIT-Touch control with air temperature probe for on board installation.
For on board installation
➔❖ LIT-Touch electronic control for 2-pipe systems, with 2 pipes with electrical resistance or 4 pipes, complete with a minimum water temperature probe, ON/OFF valve control and integrated master/slave function up to a total of 15 units.
➔❖ Additional board with 2 digital outputs that can be configured.
➔❖ On board air temperature probe.
➔❖ RS485 serial board for serial communication with other devices (Modbus RTU protocol).

Key: ❖ Factory fitted
➔ Supplied separately

YARDY-I EV3 MVP-MVT-MXP-MXT-IVP-IVF-IXP
Total cooling capacity [EN1397] kW
kW
kW
Heating capacity (45°C) [EN1397] kW
kW
kW
Heating capacity (50°C) kW
kW
kW
Heating capacity (70°C) [EN1397] kW
kW
kW
Heating capacity of additional coil (65°C) [EN1397] kW
kW
kW
Heating capacity of additional coil (70°C) [EN1397] kW
kW
kW
Air flow speed m³/h
m³/h
m³/h
Sound power dB(A)
dB(A)
dB(A)
Sound pressure dB(A)
dB(A)
dB(A)
Absorbed power W
W
W
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHTS
L - MXP-MXT-MVP-MVT width mm
L - IVP-IXP-IVF width mm
H - MXP-MXT-MVP-MVT height mm
H - IVP-IXP-IVF height mm
MVP-MVT-MXP-MXT Feet height mm
P - MXP-MXT-MVP-MVT Depth mm
P - IVP-IXP-IVF Depth mm
MXP-MXT-MVP-MVT Weight kg
IVP-IXP-IVF Weight kg
20 24 30 34 45 48 60 74 80 88
1,86 2,24 2,97 3,37 4,11 4,6 6,28 7,33 7,94 8,4
1,44 1,68 2,33 2,75 3,05 3,49 4,6 5,24 5,87 6,32
0,75 0,8 1,08 1,34 1,53 1,73 1,78 2,1 2,1 2,25
2,1 2,18 3,27 3,41 4,47 4,65 7,13 7,41 9,67 10,07
1,48 1,56 2,52 2,6 3,13 3,27 5,12 5,31 7,15 7,43
0,77 0,81 1,2 1,26 1,5 1,57 1,88 1,94 2,63 2,74
2,47 2,6 3,87 4,07 5,3 5,54 8,38 8,81 11,29 11,77
1,77 1,88 2,99 3,14 3,74 3,93 6,07 6,37 8,39 8,75
0,92 0,97 1,42 1,52 1,81 1,9 2,25 2,36 3,07 3,22
4,2 4,36 6,56 6,85 8,96 9,31 14,28 14,86 19,35 20,14
2,98 3,14 5,06 5,26 6,28 6,56 10,3 10,77 14,35 14,91
1,56 1,64 2,44 2,56 3,06 3,19 3,87 3,98 5,37 5,6
1,95 2,08 2,94 2,8 3,36 3,2 5,64 5,37 6,5 6,17
1,66 1,6 2,34 2,22 2,84 2,7 4,67 4,45 5,39 5,14
0,87 0,83 1,3 1,23 1,53 1,46 2,17 2,06 2,51 2,4
2,21 2,36 3,33 3,17 3,83 3,64 6,38 6,08 7,37 6,98
1,92 1,84 2,65 2,52 3,3 3,15 5,3 5,04 6,12 5,83
1,01 0,96 1,48 1,41 1,79 1,7 2,5 2,38 2,9 2,76
331 331 523 523 645 645 1235 1235 1503 1458
230 230 400 400 450 450 780 780 965 965
97 97 167 167 198 198 256 256 300 300
48 48 50 50 51 51 62 62 66 66
40 40 43 43 42 42 50 50 56 56
29 29 29 29 29 29 30 30 32 32
39 39 41 41 42 42 53 53 57 57
31 31 34 34 33 33 41 41 47 47
20 20 20 20 20 20 21 21 23 23
23 25 26 28 39 42 89 95 136 146
13 14 15 16 14 15 28 30 52 56
6 6 6 6 7 8 7 7 9 10
230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50
20 24 30 34 45 48 60 74 80 88
800 800 1000 1000 1200 1200 1500 1500 1500 1500
550 550 750 750 950 950 1250 1250 1250 1250
570 570 570 570 570 570 570 570 570 570
545 545 545 545 545 545 545 545 545 545
100 100 100 100 100 100 100 100 100 100
220 220 220 220 220 220 220 220 220 220
212 212 212 212 212 212 212 212 212 212
20 20,5 21 22 28 29 35 36 37 38
16,5 17 20,5 21,5 25,5 27 34,5 35,5 36,5 37,5

Data at the following conditions:

Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C.

Air: 20°C - Water: 45/40°C.

Air: 20°C - Water: 50°C, flow rate as in cooling.

Air: 20°C - Water: 70/60°C.

Air: 20°C - Water: 65/55°C.

For room volume equal to 100 m³ and reverberation time = 0.5 sec.

E

Eurovent certified performance.

Performance refers to the motor’s input signal: 10V - 6V - 1V at MAX - MED - MIN speed.

YARDY-I EV3 24 - 34 - 48 - 74 - 88 with oversized 4-row coil.

For the selection with Air’Suite filter please refer to UP-TO-DATE selection software.

For the selection with Air’Suite filter please refer to UP-TO-DATE selection software.