EasyPACK

TCAEY-THAEY 269÷2146

Cooling capacity: 63.7

144.4 kW :

Heating capacity: 70.3

151.7 kW:

WEBCODE: EAS01

Product benefits

  • Complete and flexible range of accessories and set-ups
  • Multi-purpose for systems with 2 pipes+DHW (with optional RC100)
  • Integrated MASTER/SLAVE control
  • HT65 version for 65°C water production (°)
AdesivoAfP_logo-\\ITRHREPOWEB\Archivio_immagini\LOGHI\adaptive\Etichetta AFplus bianco.tif
  • SoloRaffr_logo
  • PdC_logo
  • Install_EST_logo
  • R410A_logo
  • Eurovent_logo

Water chillers and packaged reversible air-cooled heat pumps with axial fans. Range with scroll hermetic compressors and R410A refrigerant.



Construction features

• Compressor: scroll type, rotary, hermetic complete with thermal protection and casing heater.
• 3 capacity steps with high efficiency at partial loads.
• Water side heat exchanger: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Air side heat exchanger: featuring micro-channels or finned coil with copper pipes and aluminium fins depending on models/sizes.
• Fan: external rotor axial type electric fans equipped with internal thermal protection and accident protection grilles. The electric fans, based on the versions, are fitted with a proportional electronic device for continuous regulation of the rotation speed of the fans.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: load-bearing structure made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- fan and compressor circuit breaker switches;
- display of cooling circuit high and low pressure;
- Master/Slave control up to 4 units in parallel;
- clock board;
- control of Variable Primary Flow (VPF_R).


Versions

• B - Standard version (TCAEBY).
• T - High efficiency version with oversized condensing section (TCAETY-THAETY).
• S - Silenced version complete with compressor compartment soundproofing, reduced speed fans, and oversized condensing section (TCAESY-THAESY).
• Q - Super-silenced version complete with compressor technical compartment soundproofing, super-reduced speed fans and oversized condensing section (TCAEQY-THAEQY).


Models

• TCAEBY: standard unit designed for cooling only.
• TCAETY: high efficiency unit designed for cooling only.
• TCAESY: silenced unit designed for cooling only.
• TCAEQY: super silenced unit designed for cooling only.
• THAETY: heat pump unit.
• THAESY: silenced heat pump unit.
• THAEQY: super silenced heat pump unit.


Factory fitted accessories

• Shell and tube evaporator.
• PUMP with single or double electric pump, one of which automatic in standby. The electric pumps are available in the low or high head versions.
• TANK&PUMP with 230 to 440 litre integrated buffer tank (depending on models) and single or double electric pump, complete with expansion tank, air vent valves, safety valve, and water side pressure gauge.
• Inverter pump control for unit start-up.
• Desuperheater.
• 100% heat recovery unit
• Electronic expansion valve.
• Condensing control (standard in B-S-Q versions).
• Condensing control with fans with EC motor.
• Condensing control with over-pressure fans (B-T version only)
• Power factor correction capacitors (cosφ > 0.94).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameter measuring device.
• Optimised energy efficiency.
• Soft starter.
• Technical compartment soundproofing.
• Compressor soundproof enclosures.
• Cooling circuit outlet and inlet valves.
• Refrigerant leak detector.
• Cooling circuit high and low pressure gauges.
• Double safety valves.
• Metal filters or coil protection nets.
• Microchannel coils with E-coating treatment, copper/copper or pre-painted copper/aluminium depending on the versions.
• Control of min/max power supply voltage.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Evaporator antifreeze heater, electrical panel, buffer tank, electric pumps and heat exchangers for heat recovery, if applicable.
• Buffer tank integrative heaters.
• Low temperature water production.
• Interfaces for serial communication with other devices.
• Rubber anti-vibration mounts.


Separately supplied accessories

• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.



TCAEBY MODEL
Nominal cooling capacity kW
E.E.R.
Absorbed power kW
TCAETY-TCAESY-TCAEQY MODEL
Nominal cooling capacity kW
Nominal cooling capacity kW
Nominal cooling capacity kW
E.E.R.
E.E.R.
E.E.R.
Absorbed power kW
Absorbed power kW
Absorbed power kW
THAETY-THAESY-THAEQY MODEL
Nominal heating capacity kW
Nominal heating capacity kW
Nominal heating capacity kW
C.O.P.
C.O.P.
C.O.P.
Nominal cooling capacity kW
Nominal cooling capacity kW
Nominal cooling capacity kW
Absorbed power kW
Absorbed power kW
Absorbed power kW
TCAEY-THAEY MODEL
TCAEBY sound pressure dB(A)
TCAETY-THAETY sound pressure dB(A)
TCAESY-THAESY sound pressure dB(A)
TCAEQY-THAEQY sound pressure dB(A)
TCAEBY sound power dB(A)
TCAETY-THAETY sound power dB(A)
TCAESY-THAESY sound power dB(A)
TCAEQY-THAEQY sound power dB(A)
Scroll/step compressor n.
Circuits n.
Electrical supply V-ph-Hz
DIMENSIONS AND WEIGHT
W - Width of version B mm
W - Width of version T - S - Q mm
H - Height of version B mm
H - Height of version T - S mm
H - Height of version Q mm
D - Depth of version B mm
D - Depth of version T - S - Q mm
TCAEBY weight kg
TCAETY weight kg
THAETY weight kg
SEASONAL ENERGY PERFORMANCE
TCAEBY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW
SEER  (EN 14825)
ηs,c %
TCAETY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW
SEER  (EN 14825)
ηs,c %
TCAESY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW
SEER  (EN 14825)
ηs,c %
TCAEQY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW
SEER  (EN 14825)
ηs,c %
THAETY MODEL SEASONAL ENERGY PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW
SCOP (EN 14825)
ηs %
Energy class
THAESY MODEL SEASONAL ENERGY PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW
SCOP (EN 14825)
ηs %
Energy class
THAEQY MODEL SEASONAL ENERGY PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW
SCOP (EN 14825)
ηs %
Energy class
269 279 289 296 2112 2125 2146
65,6 72,1 77,6 86,5 105,5 - -
2,74 2,81 2,81 2,62 2,79 - -
23,94 25,66 27,62 33,02 37,81 - -
269 279 289 296 2112 2125 2146
69,2 79,1 90,1 96,1 112 125,5 144,4
67,7 76,7 87,6 92,1 108 122 138,9
64,7 71,2 84,6 89,6 101,1 116,5 131
3,12 3,18 3,12 3,11 3,1 3,12 3,12
2,92 3,05 2,95 2,92 2,94 2,99 2,94
2,82 2,72 2,8 2,72 2,53 2,72 2,59
22,18 24,87 28,88 30,9 36,13 40,22 46,28
23,18 25,15 29,69 31,54 36,73 40,8 47,24
22,94 26,18 30,21 32,94 39,96 42,83 50,58
269 279 289 296 2112 2125 2146
73,4 82,4 92,4 100,5 118,5 133,1 151,7
70,8 80,4 90,4 98 115 129,1 147,6
70,3 77,3 88,4 95,4 111 125,5 143,6
3,35 3,36 3,31 3,28 3,31 3,25 3,23
3,32 3,36 3,31 3,29 3,3 3,27 3,27
3,31 3,3 3,27 3,26 3,21 3,23 3,22
67,2 76,7 86,6 93,6 107,5 121,5 139,4
66,2 74,7 85,7 89,6 104,6 119 136,9
63,7 69,7 82,7 86,6 99,1 112,1 128,5
21,91 24,52 27,92 30,64 35,8 40,95 46,97
21,33 23,93 27,31 29,79 34,85 39,48 45,14
21,24 23,42 27,03 29,26 34,58 38,85 44,6
269 279 289 296 2112 2125 2146
50 50 50 50 52 - -
50 51 51 51 53 54 54
46 47 47 47 49 50 50
42 42 43 43 46 47 47
82 82 82 82 84 - -
82 83 83 83 85 86 86
78 79 79 79 81 82 82
74 74 75 75 78 79 79
2/3 2/3 2/3 2/3 2/3 2/3 2/3
1 1 1 1 1 1 1
400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50
269 279 289 296 2112 2125 269
2650 2650 2650 2650 3250 - -
3250 3250 3250 3250 3450 3450 3450
1700 1700 1700 1700 1700 - -
1700 1700 1700 1700 2000 2000 2000
1520 1520 1520 1520 2000 2000 2000
1210 1210 1210 1210 1210 - -
1210 1210 1210 1210 1520 1520 1520
755 760 795 800 980 - -
850 865 870 905 1160 1195 1255
915 930 935 980 1240 1280 1355
269 279 289 296 2112 2125 2146
65,6 72,1 77,6 86,5 105,5 - -
4,35 4,19 4,2 4,14 4,34 - -
171 164 165 163 170 - -
69,2 79,1 90,1 96,1 112 125,5 144,4
4,43 4,35 4,45 4,48 4,46 4,41 4,44
174 171 175 176 175 173 175
67,7 76,7 87,6 92,1 108 122 138,9
4,34 4,35 4,35 4,37 4,4 4,42 4,4
170 171 171 172 173 174 173
64,7 71,2 84,6 89,6 101,1 116,5 131
4,27 4,17 4,3 4,23 4,16 4,17 4,11
168 164 169 166 163 164 161
53 60 67 91 108 121 138
4,07 4,04 3,99 3,9 4,03 3,9 3,87
160 159 156 153 158 153 152
A++ A++ A++ - - - -
51 58 66 89 104 117 134
4,05 4,08 4 3,93 4,02 3,96 3,93
159 160 157 154 158 155 154
A++ A++ A++ - - - -
51 56 65 69 100 114 130
4,06 4,04 3,99 3,99 3,93 3,92 3,88
159 159 157 157 154 154 152
A++ A++ A++ A++ - - -

Data at the following conditions:

Air: 35°C - Water: 12/7°C

Air: 7°C, D.B. - 6°C W.B.- Water: 40/45°C.

In open field (Q = 2) at 10 m from the unit.

Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.

Weight referred to the unit without load and not accessorised.

TCAESY-THAESY silenced versions.

TCAEQY-THAEQY super-silenced versions.

Performance according to EN 14511.

Low temperature application (7°C)

Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)

In Average climatic conditions, low temperature application (35°C)

Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/2013 and No.813/2013)

References

08 October 2021

PICTURE ORGANIC CLOTHING

France

30 August 2019

Electronic Company

FRANCE

18 September 2017

3D Innovation Center

GERMANY