Web code 245÷2185: YFC21 Web code 4180÷4360: YFC31
CHILLERS HEAT PUMPS WATER-cooled CONDENSERLESS UNITS

Y-Flow E

TCEEBY 245÷4360
Cooling capacity 39,8÷320,9 kW

Cooling only condenserless units to couple with remote condensers. Range with scroll hermetic compressors and R410A refrigerant gas.

Features

Key features

Built-in MASTER/SLAVE control

Y-Flow E

Description

Construction features

• Compressor: hermetic rotary scroll complete with thermal protection and crankcase heater.
• Water side heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch.
• Control: microprocessor electronic control, with Adaptive Function Plus logic.
• Structure: made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- compressor circuit breaker switches;
- display of cooling circuit high and low pressure;
- Master/Slave control up to 4 units in parallel;
- clock board;
- 0-10V analogue signal for condensing control from external device.

Models

• TCEEBY: unit designed for cooling only.

Factory fitted accessories

• PUMP primary side (user): pump unit complete with single or double electric circulation pump, membrane expansion tank, safety valve, water fill/drain valve, manual air vent valve and pressure gauge. The electric pumps are available with low or high head.
• VPF control.
• Inverter pump control for unit start-up.
• Power factor correction capacitors (cosφ > 0.94)
• Cooling circuit high and low pressure gauges.
• Power factor correction capacitors.
• Soft start device.
• Forced limit of power consumption.
• Energy parameter measuring device.
• Control of min/max power supply voltage.
• Double safety valves.
• Silenced set up.
• Interfaces for serial communication with other devices.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Rubber anti-vibration mounts (or spring-operated for models 4180-4360) supplied unassembled.

Separately supplied accessories

• Outdoor air temperature probe for set-point compensation.
• Water filter.
• Rubber anti-vibration mounts.
• Clock board.
• Remote keypad with display.
• Serial converter (RS485/USB).

Technical data

TCEEBY MODEL 245 250 260 270 275 290 2100 2115 2130 2145 2165 2185 4180 4205 4235 4260 4290 4330 4360
Nominal cooling capacity kW 39,8 47,3 53,6 61,3 67,9 80,6 91,7 103,4 115 128,2 145,7 162,3 161,2 182,9 205 229,4 253,8 287,4 320,9
EER 3,29 3,38 3,3 3,76 3,39 3,49 3,38 3,34 3,29 3,34 3,26 3,19 3,53 3,5 3,48 3,49 3,5 3,42 3,36
Absorbed power (*) kW 12,1 14 16,2 18,2 20 23,1 27,1 31 35 38,4 44,7 50,8 45,7 52,3 58,9 65,8 72,6 84 95,5
Available head of standard electric pump kPa 116 108 134 94 84 86 117 119 133 117 119 106 140 132 114 117 111 136 168
Available head of high head pump kPa 182 187 171 185 177 180 169 178 190 176 177 172 195 200 196 240 273 241 257
Sound power dB(A) 67 67 68 68 69 70 71 72 73 74 74 75 77 77 78 79 80 81 82
Silenced setup sound power dB(A) 63 63 64 64 65 66 67 68 69 70 70 71 75 75 76 77 78 79 80
Scroll/ step compressors n. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 4/4 4/4 4/4 4/4 4/4 4/4 4/4
Circuits n. 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2
Electrical supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
DIMENSIONS AND WEIGHTS 245 250 260 270 275 290 2100 2115 2130 2145 2165 2185 4180 4205 4235 4260 4290 4330 4360
L – Width mm 1020 1020 1020 1020 1020 1020 1270 1270 1270 1270 1270 1270 2600 2600 2600 2600 2600 2600 2600
W – Width (PUMP setup) mm 1250 1250 1250 1250 1250 1250 1500 1500 1500 1500 1500 1500 3734 3734 3734 3734 3734 3734 3734
H – Height mm 1470 1470 1470 1470 1470 1470 1620 1620 1620 1620 1620 1620 1860 1860 1860 1860 1860 1860 1860
P – Depth mm 870 870 870 870 870 870 870 870 870 870 870 870 870 870 870 870 870 870 870
Weight kg 380 390 390 400 400 420 660 670 690 710 720 720 1310 1370 1390 1410 1440 1460 1490
Recommended combinations with CCAMY condensers for TCEEBY models 4180-4360
TCEEBY MODEL 4180 4205 4235 4260 4290 4330 4360
CCAMY MODEL Circuit 1 CCAMY 290 CCAMY 2110 CCAMY 2115 CCAMY 2130 CCAMY 2145 CCAMY 2165 CCAMY 2185
Circuit 2 CCAMY 290 CCAMY 2110 CCAMY 2115 CCAMY 2130 CCAMY 2145 CCAMY 2165 CCAMY 2185
SEASONAL ENERGY PERFORMANCE 4180 4205 4235 4260 4290 4330 4360
TCEEBY + CCAMBY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 160,6 182,2 204,2 228,5 252,9 286,3 319,7
SEER  (EN 14825) 4,19 4,22 4,24 4,25 4,26 4,27 4,22
ηs,c % 165 166 167 167 167 168 166
TCEEBY + CCAMSY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 160,6 182,2 204,2 228,5 252,9 286,3 319,7
SEER  (EN 14825) 4,18 4,21 4,23 4,22 4,24 4,24 4,2
ηs,c % 164 165 166 166 167 167 165
TCEEBY + CCAMQY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 160,6 182,2 204,2 228,5 252,9 286,3 319,7
SEER  (EN 14825) 4,14 4,18 4,19 4,2 4,23 4,22 4,19
ηs,c % 163 164 165 165 166 166 165
  • Data at the following conditions:
  • Chilled water: 12/7°C – Condensing temperature: 50°C (dew point)
  • Sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN ISO 9614
  • Weight referred to the unit without load and not accessorised.
  • (*) Unit without electric pumps.
  • Low temperature application (7°C)
  • Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: tif
Request information about this product








    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.