Web code 245÷2185: YF021 Web code 4180÷4410: YF031
CHILLERS HEAT PUMPS WATER-cooled CONDENSERLESS UNITS

Y-Flow

TCHEY 245÷4360 / THHEY 245÷4410
Cooling capacity 41,2÷373,9 kW
Heating capacity 50,2÷464,4 kW

Packaged water-cooled water chillers and reversible heat pumps on the cooling circuit with water-cooling system. Range with scroll hermetic compressors and R410A refrigerant gas.

Features

Tax incentives*

Key features

Applications with well water, water mains or geothermal probes
Integrated MASTER/SLAVE control
HT65 version for 65°C water production (°)

Y-Flow

Description

Construction features

• Compressor: hermetic rotary scroll complete with thermal protection and crankcase heater.
• Primary side (user) heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch.
• Disposal unit side (well/mains/geothermal probes) heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch (for THHEY).
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- compressor circuit breaker switches;
- display of cooling circuit high and low pressure;
- Master/Slave control up to 4 units in parallel;
- clock board;
- 0-10V analogue signal for condensing/evaporating control performed by external device;
- control of Variable Primary Flow (VPF_R).

Versions

• LT - Hot water production up to 52°C.
• HT - Hot water production up to 55°C.

Models

• TCHEY: unit designed for cooling only.
• THHEY: heat pump unit.

Factory fitted accessories

• PUMP primary side (user): with single or double electric pump, including an automatic pump in standby, complete with expansion tank, safety valve, water fill/drain valve, air vent valve and pressure gauge. The electric pumps are available in the low or high pressure head versions. ➔
• PUMP disposal side (geothermal probes/dry cooler): with single or double electric pump regulated via inverter including an automatic actuation pump in standby. ➔
• Desuperheater. ➔
• 100% heat recovery unit (mod. 245-4360). ➔
• Set up for heat pump operation (for TCHEY only).
• Inverter pump control for unit start-up.
• Power factor correction capacitors (cosφ > 0.94).
• Soft-starter.
• Energy parameter measuring device.
• Cooling circuit outlet and inlet valves.
• Refrigerant leak detector.
• Forced limit of power consumption.
• Cooling circuit high and low pressure gauges.
• Double safety valves.
• Silenced set up.
• Control of min/max power supply voltage.
• Low temperature water production.
• Digital input for double set-point.
• 4-20mA analogue signal for shifting set-point.
• Interfaces for serial communication with other devices.
• Rubber anti-vibration mounts.

Separately supplied accessories

• 3-way modulating condensing control valve.
• 2-way modulating condensing control valve.
• Outdoor air temperature probe for set-point compensation.
• Free-cooling kit (mod. 245-2185).
• Water filter.
• Remote keypad with display.
• Thermostat with display.
• Serial converter (RS485/USB).
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.

Technical data

TCHEY HT MODEL 245 250 260 270 275 290 2100 2115 2130 2145 2165 2185 4180 4205 4235 4260 4290 4330 4360 4410
Cooling capacity kW 45,1 53,1 60,4 69 75,6 89,8 102,8 117 130,7 145,4 165,1 184,3 180,9 206,9 232,6 260,2 287,5 326 363,1 -
Absorbed power kW 9,8 11,34 13,1 14,93 16,39 19,1 22,34 25,43 28,78 31,67 36,85 41,79 37,45 42,83 48,25 54,2 60,27 69,36 79,1 -
E.E.R. 4,6 4,68 4,61 4,62 4,61 4,7 4,6 4,6 4,54 4,59 4,48 4,41 4,83 4,83 4,82 4,8 4,77 4,7 4,59 -
THHEY HT MODEL 245 250 260 270 275 290 2100 2115 2130 2145 2165 2185 4180 4205 4235 4260 4290 4330 4360 4410
Heating capacity kW 50,2 59 67,8 75,6 84 102,2 116,5 133,6 147,7 163,2 186,6 209,4 201,8 230,5 258,7 291,7 323,7 369 413,8 464,1
Absorbed power kW 12,18 13,91 15,87 17,66 19,85 23,76 28,2 31,36 35,25 39,32 45,73 51,96 45,55 52,86 60,3 67,83 75,63 87,64 99,23 116,6
C.O.P. 4,12 4,24 4,27 4,28 4,23 4,3 4,13 4,26 4,19 4,15 4,08 4,03 4,43 4,36 4,29 4,3 4,28 4,21 4,17 3,98
Cooling capacity kW 41,3 48,5 55,2 63 69,2 82 96,1 109,3 120,8 134,5 152,4 170,1 160,7 183,7 206,8 231,7 255,4 293 330,4 374
E.E.R. 4,32 4,38 4,36 4,31 4,31 4,31 4,3 4,35 4,3 4,29 4,08 4,02 4,42 4,29 4,22 4,19 4,16 4,14 4,16 4,1
TCHEY – THHEY MODEL 245 250 260 270 275 290 2100 2115 2130 2145 2165 2185 4180 4205 4235 4260 4290 4330 4360 4410
Sound power dB(A) 67 67 68 68 69 70 71 72 73 74 74 75 77 77 78 79 80 81 82 83
Scroll compressors/steps n. 2/2 2/2 2/2 2/2 2/3 2/2 2/3 2/3 2/3 2/2 2/3 2/2 4/4 4/4 4/4 4/4 4/4 4/4 4/4 4/4
Circuits n. 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2
Electrical supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
DIMENSIONS AND WEIGHTS 245 250 260 270 275 290 2100 2115 2130 2145 2165 2185 4180 4205 4235 4260 4290 4330 4360 4410
L – Width mm 1020 1020 1020 1020 1020 1020 1270 1270 1270 1270 1270 1270 2600 2600 2600 2600 2600 2600 2600 2600
L – Width mm 1250 1250 1250 1250 1250 1250 1500 1500 1500 1500 1500 1500 3734 3734 3734 3734 3734 3734 3734 3734
H – Height mm 1470 1470 1470 1470 1470 1470 1620 1620 1620 1620 1620 1620 1860 1860 1860 1860 1860 1860 1860 1860
P – Depth mm 870 870 870 870 870 870 870 870 870 870 870 870 870 870 870 870 870 870 870 870
Weight TCHEY LT kg 395 405 410 425 435 450 695 710 730 755 770 775 1350 1410 1440 1460 1500 1530 1570 -
Weight TCHEY HT kg 425 430 440 460 470 480 740 770 800 825 850 855 1440 1470 1510 1540 1600 1650 1680 -
Weight THHEY LT kg 405 415 425 440 450 460 700 720 750 755 790 800 1380 1440 1470 1500 1530 1560 1600 1750
Weight THHEY HT kg 435 445 455 470 480 495 755 790 820 845 870 880 1470 1500 1550 1570 1630 1680 1720 1790
SEASONAL ENERGY PERFORMANCE 245 250 260 270 275 290 2100 2115 2130 2145 2165 2185 4180 4205 4235 4260 4290 4330 4360 4410
TCHEY HT MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 45,1 53,1 60,4 69 75,6 89,8 102,8 117 130,7 145,4 165,1 184,3 180,9 206,9 232,6 260,2 287,5 326 363,1 -
SEER  (EN 14825) 5,75 5,98 6,08 5,94 6,26 6,04 6,02 6,17 6,1 6,01 6,2 5,9 5,89 6,1 6,3 6,32 6,36 6,28 6,21 -
ηs,c % 227 236 240 235 248 239 238 244 241 237 245 233 233 241 249 250 251 248 245 -
THHEY HT MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW - - - - - - - - - - - - - - - - 255,4 293 330,4 374
SEER  (EN 14825) - - - - - - - - - - - - - - - - 6,05 6 6,11 5,7
ηs,c % - - - - - - - - - - - - - - - - 239 237 241 225
THHEY HT MODEL SEASONAL PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW 61 71 81 91 101 122 140 159 174 196 224 250 262 302 340 383 - - - -
SCOP (EN 14825) 6,54 6,59 6,48 6,46 6,72 6,38 6,1 6,38 6,16 6,1 6,16 5,89 6,93 6,68 6,54 6,52 - - - -
ηs % 254 255 251 251 261 247 236 247 239 236 239 228 269 259 253 253 - - - -
Energy class A+++ - - - - - - - - - - - - - - - - - - -
  • Data at the following conditions:
  • Chilled water: 12/7℃. – Condenser water: 30/35°C.
  • Hot water: 40/45°C. – Evaporator water: 10/7℃.
  • Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
  • Width referring to the unit with standard setup or supplied with “recovery” or “desuperheater” accessories.
  • Width referring to the PUMP setup, up to a maximum of 2 pumps in mod. 245-2185 (2 user side or disposal unit side pumps or 1 user side pump + 1 disposal unit side pump) and up to a maximum of 4 pumps in mod. 4180-4410 (2 pumps on user side and 2 pumps on disposal unit side).
  • Empty weight
  • Performance according to EN 14511.
  • Low temperature application (7°C)
  • Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)
  • In Average climatic conditions, low temperature application (35°C)
  • Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/2013 and No.813/2013)

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: tif
Request information about this product








    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.