Web code: WKE07
CHILLERS HEAT PUMPS AIR-cooled AXIAL fans

WinPACK-P

TCAEP-THAEP 4200÷6430
Cooling capacity 188,7÷430,7 kW
Heating capacity 198,3÷435,3 kW

Packaged reversible air-cooled heat pumps with axial fans. Range with hermetic scroll compressors and R290 refrigerant.

Features

Key features


Efficient range in R290

Full optional unit

Integrated MASTER/SLAVE control

Hot water production from -20°C to 40°C outdoor air

Temperature of the produced water up to 75°C


WinPACK-P

Description

Construction features

• Compressor: hermetic rotary, scroll type, complete with thermal protection and casing heater.
• 4÷6 capacity steps with high efficiency at partial loads.
• Water side heat exchanger: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Air side heat exchanger: featuring micro-channels (TCAEP) or finned coil with copper pipes and aluminium fins (THAEP).
• Fan: external rotor axial type electric fans equipped with internal thermal protection, accident protection grilles and proportional electronic device for continuous fan rotation speed adjustment.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: load-bearing structure made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- compressor and fan circuit breaker switches;
- electronic expansion valve;
- display of cooling circuit high and low pressure;
- Master/Slave control up to 4 units in parallel;
- clock board;
- control of Variable Primary Flow (VPF_R).

Versions

• T - High efficiency version (TCAETP-THAETP).
• Q - Super silenced version complete with compressor technical compartment soundproofing and reduced speed fans (TCAEQP-THAEQP).

Models

• TCAETP: high efficiency unit designed for cooling only.
• TCAEQP: super silenced unit designed for cooling only.
• THAETP: heat pump unit.
• THAEQP: super silenced heat pump unit.

Factory fitted accessories

• PUMP with single or double electric pump, one of which automatic in standby. The electric pumps are available in the low or high head versions.
• TANK&PUMP with 700 litre integrated buffer tank and single or double electric pump, complete with expansion tank, air vent valves, safety valve and water side pressure gauge.
• Inverter pump control for unit start-up.
• Desuperheater.
• 100% heat recovery unit (TCAEP)
• Condensing control with fans with EC motor.
• Condensing control with over-pressure fans (T version only)
• Power factor correction capacitors (cosφ > 0.94).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameter measuring device.
• Soft starter.
• Technical compressor compartment soundproofing.
• Compressor soundproof enclosures.
• Double safety valves.
• Buffer panels.
• Microchannel coils with E-coating treatment, copper/copper, copper/aluminium, pre-painted copper/aluminium or with hydrophilic treatment depending on versions.
• Control of min/max power supply.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Contacts for Smart Grid integration and photovoltaic system.
• Evaporator antifreeze heater, electrical panel, buffer tank, electric pumps and heat exchangers for heat recovery, if applicable, and base.
• Low temperature water production.
• Interfaces for serial communication with other devices.
• Colour touch user keypad (fitted on the machine or remotely) with 7'' display.
• Anti-vibration mounts.

Separately supplied accessories

• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.

Technical data

TCAETP-TCAEQP MODEL 4200 4220 4250 4270 4290 5320 5360 6380 6430
❶ Nominal cooling capacity kW 199,7 220,7 249,7 270,7 291,7 321,7 360,7 385,7 430,7
❶ Nominal cooling capacity kW 194,7 213,7 244,7 263,7 283,7 314,7 351,7 375,7 417,7
❶ E.E.R. 3,16 3,1 3,23 3,19 3,15 3,25 3,14 3,13 3,1
❶ E.E.R. 3,01 2,91 3,12 3,06 3,02 3,14 3,02 3 2,92
❶ Absorbed power kW 63,2 71,2 77,3 84,9 92,6 99 114,9 123,2 138,9
❶ Absorbed power kW 64,7 73,4 78,4 86,2 93,9 100,2 116,5 125,2 143
THAETP-THAEQP MODEL 4200 4220 4250 4270 4290 5320 5360 6380 6430
❷ Nominal heating capacity kW 201,3 220,3 256,3 276,3 295,3 332,3 372,3 397,3 435,3
❷ Nominal heating capacity kW 198,3 216,3 252,3 271,3 291,3 328,3 365,3 390,3 427,3
❷ C.O.P. 3,29 3,28 3,32 3,31 3,3 3,31 3,31 3,3 3,29
❷ C.O.P. 3,3 3,28 3,34 3,32 3,32 3,36 3,33 3,32 3,3
❶ Nominal cooling capacity kW 193,7 213,7 241,6 261,7 282,7 311,7 348,7 373,7 415,7
❶ Nominal cooling capacity kW 188,7 207,7 236,6 255,6 275,7 304,6 340,6 363,6 404,7
❶ E.E.R. 3,03 2,96 3,07 3,04 3,02 3,1 3 2,99 2,95
❶ E.E.R. 2,87 2,81 2,97 2,93 2,9 3 2,89 2,87 2,81
❷ Absorbed power kW 61,2 67,2 77,2 83,5 89,5 100,4 112,5 120,4 132,3
❷ Absorbed power kW 60,1 65,9 75,5 81,7 87,7 97,7 109,7 117,6 129,5
TCAEP-THAEP MODEL 4200 4220 4250 4270 4290 5320 5360 6380 6430
❸ TCAETP-THAETP sound pressure dB(A) 58 59 60 60 61 61 62 62 62
❸ TCAEQP-THAEQP sound pressure dB(A) 52 53 54 54 55 55 56 56 57
❹ TCAETP-THAETP sound power dB(A) 90 91 92 92 93 93 94 94 94
❹ TCAEQP-THAEQP sound power dB(A) 84 85 86 86 87 87 88 88 89
Scroll compressors/steps n. 4/4 4/4 4/4 4/4 4/4 5/5 5/5 6/6 6/6
Circuits n. 2 2 2 2 2 2 2 2 2
Electrical supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
DIMENSIONS AND WEIGHTS 4200 4220 4250 4270 4290 5320 5360 6380 6430
L – Width mm 2730 2730 3830 3830 3830 4970 4970 4970 4970
❺ L – Width TCAEP mm 3750 3750 3830 3830 3830 4970 4970 4970 4970
❺ L – Width THAEP mm 3750 3750 4850 4850 4850 4970 4970 4970 4970
H – Height mm 2480 2480 2480 2480 2480 2480 2480 2480 2480
P – Depth mm 2260 2260 2260 2260 2260 2260 2260 2260 2260
❻ TCAETP weight kg 1875 2000 2555 2670 2785 3315 3545 3600 3820
❻ TCAEQP weight kg 1935 2060 2640 2755 2870 3420 3650 3705 3925
❻ THAETP weight kg 2230 2360 3030 3160 3285 3905 4155 4175 4435
❻ THAEQP weight kg 2310 2440 3135 3265 3390 4045 4295 4315 4575
SEASONAL ENERGY PERFORMANCE 4200 4220 4250 4270 4290 5320 5360 6380 6430
TCAETP MODEL SEASONAL PERFORMANCE IN COOLING MODE
① Pdesignc (EN 14825) kW 199,7 220,7 249,7 270,7 291,7 321,7 360,7 385,7 430,7
① SEER  (EN 14825) 4,64 4,65 4,78 4,66 4,52 4,7 4,57 4,72 4,61
② ηs,c % 183 183 188 183 178 185 180 186 181
TCAEQP MODEL SEASONAL PERFORMANCE IN COOLING MODE
① Pdesignc (EN 14825) kW 194,7 213,7 244,7 263,7 283,7 314,7 351,7 375,7 417,7
① SEER  (EN 14825) 4,57 4,59 4,77 4,62 4,47 4,67 4,51 4,7 4,58
② ηs,c % 180 180 188 182 176 184 177 185 180
THAETP MODEL SEASONAL PERFORMANCE IN HEATING MODE – Low temperature application 35°C
③ Pdesignh (EN 14825) kW 165 181 209 226 242 272 305 326 357
③ SCOP (EN 14825) 3,99 4,02 4,03 3,98 3,96 3,96 3,96 4,02 3,97
④ ηs % 156 158 158 156 155 155 156 158 156
THAEQP MODEL SEASONAL PERFORMANCE IN HEATING MODE – Low temperature application 35°C
③ Pdesignh (EN 14825) kW 162 177 206 222 238 269 299 320 349
③ SCOP (EN 14825) 3,93 3,96 3,97 3,91 3,91 3,91 3,91 3,96 3,91
④ ηs % 154 155 156 153 153 153 153 155 153
THAETP MODEL SEASONAL PERFORMANCE IN HEATING MODE – Medium temperature application 55°C
③ Pdesignh (EN 14825) kW 163 178 203 219 234 263 295 317 347
③ SCOP (EN 14825) 3,2 3,24 3,29 3,27 3,26 3,23 3,26 3,29 3,25
④ ηs % 125 127 129 128 127 126 128 128 127
THAEQP MODEL SEASONAL PERFORMANCE IN HEATING MODE – Medium temperature application 55°C
③ Pdesignh (EN 14825) kW 161 175 201 216 232 261 289 312 340
③ SCOP (EN 14825) 3,16 3,18 3,23 3,19 3,19 3,19 3,22 3,23 3,2
④ ηs % 123 124 126 125 125 125 126 126 125
  • Data at the following conditions:
  • ❶ Air: 35°C – Water: 12/7°C
  • ❷ Air: 7°C, D.B. – 6°C W.B.- Water: 40/45°C.
  • ❸ In open field (Q = 2) at 10 m from the unit.
  • ❹ Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
  • ❺ Width with ASP-ASDP accessory
  • ❻ Weight referred to the unit without load and not accessorised.
  • ■ TCAEQP-THAEQP super-silenced versions.
  • Performance according to EN 14511.
  • ① Low temperature application (7°C)
  • ② Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)
  • ③ In Average climatic conditions
  • ④ Seasonal energy efficiency: heating in Average climate (EU Regulations No.811/2013 and No.813/2013)

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: TIF
Request information about this product









    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.