New
Web code: UPI07
CHILLERS HEAT PUMPS AIR-cooled AXIAL fans

UniPACK-PI

TCAIP-THAIP 175÷3150
Cooling capacity 66,9÷153,9 kW
Heating capacity 72,1÷159,2 kW

Water chillers and packaged reversible air-cooled heat pumps with axial fans. Range with hermetic scroll compressors, DC Inverter and R290 refrigerant.

Features

Key features


Efficient and eco-friendly range in R290

Inverter technology

Full optional unit

Integrated MASTER/SLAVE control

Hot water production from -20°C to 40°C outdoor air

Temperature of the produced water up to 78°C


UniPACK-PI

Description

Construction features

• Compressor: hermetic rotary, scroll type and with Inverter actuation (i, 1+i, 2+i) complete with thermal protection and casing heater.
• Continuous regulation with high efficiency at partial loads.
• Water side heat exchanger: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Air side heat exchanger: featuring micro-channels (TCAIP) or finned coil with copper pipes and aluminium fins (THAIP).
• Fan: external rotor axial type electric fans equipped with internal thermal protection, accident protection grilles and proportional electronic device for continuous fan rotation speed regulation.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: load-bearing structure made of galvanised and painted steel plate with polyester powder coating.
• Refrigerant leak detector.
• Coil protection nets.
• The unit is also complete with:
- compressor and fan circuit breaker switches;
- electronic expansion valve;
- display of cooling circuit high and low pressure;
- Master/Slave control up to 4 units in parallel;
- clock board;
- control of Variable Primary Flow (VPF_R);
- automatic management of anti-legionella cycles.

Versions

• T - High efficiency version with oversized condensing section (TCAITP-THAITP).
• Q - Super-silenced version complete with compressor technical compartment soundproofing, reduced speed fans and oversized condensing section (THAITP-THAIQP).

Models

• TCAITP: high efficiency unit designed for cooling only.
• TCAIQP: super silenced unit designed for cooling only.
• THAITP: high efficiency heat pump unit.
• THAIQP: super silenced heat pump unit.

Factory fitted accessories

• PUMP with single or double electric pump, one of which automatic in standby. The electric pumps are available in the low or high head versions.
• TANK&PUMP with 250 - 380 litre integrated buffer tank (depending on the sizes) and single or double electric pump, complete with expansion tank, air vent valves, safety valve and water side pressure gauge.
• Inverter pump control for unit start-up.
• Desuperheater.
• 100% heat recovery unit (TCAIP)
• Condensing control with fans with EC motor.
• Condensing control with over-pressure fans (T version only)
• Power factor correction capacitors (cosφ > 0.94).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameter measuring device.
• Soft starter.
• Technical compressor compartment soundproofing.
• Compressor soundproof enclosures.
• Double safety valves.
• Buffer panels.
• Microchannel coils with E-coating treatment, copper/copper, copper/aluminium, pre-painted copper/aluminium or with hydrophilic treatment depending on versions.
• Control of min/max power supply voltage and backup battery
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Contacts for Smart Grid integration and photovoltaic system.
• Evaporator antifreeze heater, electrical panel, buffer tank, electric pumps and heat exchangers for heat recovery, if applicable, and base.
• Low temperature water production.
• Interfaces for serial communication with other devices.
• Colour touch user keypad (fitted on the machine or remotely) with 7'' display.
• Anti-vibration mounts.

Separately supplied accessories

• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.

Technical data

TCAITP-TCAIQP MODEL 175 290 2100 3110 3120 3130 3140 3150
Nominal cooling capacity kW 74,9 89,9 99,9 109,9 119,9 129,9 140,9 153,9
Nominal cooling capacity kW 68,9 82,9 91,9 100,9 108,9 119,9 129,9 140,9
E.E.R. 3,07 3,36 3,22 3,16 3,15 3,29 3,24 3,21
E.E.R. 3,08 3,4 3,3 3,04 3,05 3,28 3,18 3,15
Absorbed power kW 24,4 26,8 31 34,8 38,1 39,5 43,5 47,9
Absorbed power kW 22,4 24,4 27,8 33,2 35,7 36,6 40,8 44,7
THAITP-THAIQP MODEL 175 290 2100 3110 3120 3130 3140 3150
Nominal heating capacity kW 79,1 90,1 101,1 110,1 122,1 132,1 144,1 159,2
Nominal heating capacity kW 72,1 83,1 92,1 105,1 115,1 121,1 133,1 145,1
C.O.P. 3,25 3,26 3,21 3,23 3,21 3,29 3,25 3,24
C.O.P. 3,29 3,36 3,31 3,36 3,35 3,34 3,3 3,28
Nominal cooling capacity kW 71,9 84,9 95,9 104,9 113,9 123,9 133,9 146,9
Nominal cooling capacity kW 66,9 78,9 87,9 96,9 103,9 114,9 123,9 134,9
Absorbed power kW 24,3 27,6 31,5 34,1 38 40,2 44,3 49,1
Absorbed power kW 21,9 24,7 27,8 31,3 34,4 36,3 40,3 44,2
TCAIP-THAIP MODEL 175 290 2100 3110 3120 3130 3140 3150
TCAITP-THAITP sound pressure dB(A) 55 54 55 55 55 55 56 57
TCAIQP-THAIQP sound pressure dB(A) 50 49 50 50 50 50 51 52
TCAITP-THAITP sound power dB(A) 87 86 87 87 87 87 88 89
TCAIQP-THAIQP sound power dB(A) 82 81 82 82 82 82 83 84
Scroll compressors/steps n. 1 inverter 1 inverter + 1 1 inverter + 1 1 inverter + 2 1 inverter + 2 1 inverter + 2 1 inverter + 2 1 inverter + 2
Circuits n. 1 2 2 2 2 2 2 2
Electrical supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
DIMENSIONS AND WEIGHTS 175 290 2100 3110 3120 3130 3140 3150
L – Width mm 3250 3250 3250 3250 3250 3930 3930 3930
H – Height mm 2260 2260 2260 2260 2260 2260 2260 2260
P – Depth mm 1270 1970 1970 1970 1970 1970 1970 1970
TCAITP weight kg 1025 1495 1510 1595 1620 1835 1860 1865
THAITP weight kg 1215 1695 1730 1815 1860 2105 2130 2135
SEASONAL ENERGY PERFORMANCE 175 290 2100 3110 3120 3130 3140 3150
TCAITP MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 74,9 89,9 99,9 109,9 119,9 129,9 140,9 153,9
SEER  (EN 14825) 5,14 4,81 4,75 4,53 4,62 4,67 4,63 4,76
ηs,c % 202 189 187 178 182 184 182 187
TCAIQP MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 68,9 82,9 91,9 100,9 108,9 119,9 129,9 140,9
SEER  (EN 14825) 5,17 4,83 4,79 4,6 4,67 4,72 4,68 4,81
ηs,c % 204 190 188 181 184 186 184 189
THAITP MODEL SEASONAL PERFORMANCE IN HEATING MODE – Low temperature application 35°C
Pdesignh (EN 14825) kW 65 74 83 90 100 108 118 130
SCOP (EN 14825) 4,31 3,9 3,91 4,11 4,13 4,07 4,11 4,14
ηs % 170 153 154 162 162 160 161 163
Energy class A++ - - - - - - -
THAIQP MODEL SEASONAL PERFORMANCE IN HEATING MODE – Low temperature application 35°C
Pdesignh (EN 14825) kW 59 68 75 86 94 99 109 119
SCOP (EN 14825) 4,37 3,91 3,94 4,15 4,17 4,13 4,15 4,2
ηs % 172 153 155 163 164 162 163 165
Energy class A++ A++ - - - - - -
THAITP MODEL SEASONAL PERFORMANCE IN HEATING MODE – Medium temperature application 55°C
Pdesignh (EN 14825) kW 62 72 81 88 98 105 116 128
SCOP (EN 14825) 3,57 3,25 3,25 3,37 3,38 3,42 3,38 3,45
ηs % 140 127 127 132 132 134 132 135
Energy class A++ - - - - - - -
THAIQP MODEL SEASONAL PERFORMANCE IN HEATING MODE – Medium temperature application 55°C
Pdesignh (EN 14825) kW 56 66 74 84 93 97 107 117
SCOP (EN 14825) 3,56 3,22 3,23 3,4 3,39 3,36 3,39 3,38
ηs % 139 126 126 133 133 131 133 132
Energy class A++ A++ - - - - - -
  • Data at the following conditions:
  • Air: 35°C – Water: 12/7°C
  • Air: 7°C, D.B. – 6°C W.B.- Water: 40/45°C.
  • In open field (Q = 2) at 10 m from the unit.
  • Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
  • Weight referred to the unit without load and not accessorised.
  • TCAIQP-THAIQP super-silenced versions.
  • Performance according to EN 14511.
  • Low temperature application (7°C)
  • Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)
  • In Average climatic conditions
  • Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/2013 and No.813/2013 – class between D and A+++)

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: TIF
Request information about this product









    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.