MidiFLOW-PI
TCHITP-THHITP 115÷145-
THHITP 145 with accessory VE
Packaged water-cooled water chillers and reversible heat pumps on the cooling circuit with water-cooling system. Range with scroll hermetic compressors, DC inverter and R290 refrigerant gas.
Key features
Efficient and eco-friendly range in R290
Applications with well water, water mains, geothermal probes or dry cooler
Ventilated enclosure or outdoor installation
Plug&Play unit with integrated hydraulic module
Temperature of the produced water up to 80°C
Integrated MASTER/SLAVE control
Description
Construction features
• Compressor: hermetic rotary, scroll type with inverter actuation, complete with thermal protection and casing heater.
• Primary side (user) heat exchanger: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Disposal side heat exchanger (well, mains, geothermal probes or dry cooler): with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: made of galvanised and painted steel plate with polyester powder coating.
• Refrigerant leak detector.
• The unit is also complete with:
- electronic expansion valve;
- display of cooling circuit high and low pressure;
- Master/Slave control up to 4 units in parallel;
- clock board;
- 0-10V analogue signal for condensing/evaporating control performed by external device;
- automatic management of anti-legionella cycles.
Versions
• T - High efficiency version
Models
• TCHITP: unit designed for cooling only.
• THHITP: heat pump unit.
PUMP set up
Primary side (user): single electric pump, available with INVERTER operation.
Disposal side (well, mains, geothermal probes or dry cooler): single electric pump, available with INVERTER operation.
Factory fitted accessories
• Set-up for outdoor installation.
• Set-up for ventilated enclosure installation.
• Free-Cooling Management.
• Dry-Cooler Management.
• Setup for heat pump operation (only for TCHITP).
• Energy parameter measuring device.
• Forced limit of power consumption.
• Double safety valves.
• Silenced set up.
• Control of min/max power supply voltage.
• Low temperature water production.
• Digital input for double set-point.
• 4-20mA analogue signal for shifting set-point.
• Contacts for Smart Grid integration and photovoltaic system.
• Heat exchanger, electrical panel and electric pumps antifreeze heaters, if applicable.
• Interfaces for serial communication with other devices.
• Colour touch user keypad (remotely) with 7'' display.
Separately supplied accessories
• 3-way modulating condensing control valve.
• 2-way modulating condensing control valve.
• 3-way valve for the production of domestic hot water, managed by the adjustment.
• Outdoor air temperature probe for set-point compensation.
• Rubber anti-vibration mounts.
• Water filter.
• Air inlet fitting.
• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.
Technical data
| TCHITP MODEL | 115 | 120 | 125 | 130 | 135 | 140 | 145 | ||||
| ❶ | Cooling capacity | kW | 16,6 | 20,1 | 28,2 | 32,5 | 35 | 40,6 | 45,9 | ||
| ❶ | Absorbed power | kW | 3,34 | 4,25 | 5,57 | 6,87 | 8,06 | 8,42 | 10,38 | ||
| ❶ | E.E.R. | 4,97 | 4,73 | 5,06 | 4,73 | 4,34 | 4,82 | 4,42 | |||
| THHITP MODEL | 115 | 120 | 125 | 130 | 135 | 140 | 145 | ||||
| ❷ | Heating capacity | kW | 17,6 | 21,7 | 30,1 | 35,1 | 39,2 | 44,7 | 51,2 | ||
| ❷ | Absorbed power | kW | 4,23 | 5,34 | 7,02 | 8,54 | 9,97 | 10,44 | 12,8 | ||
| ❷ | C.O.P. | 4,16 | 4,06 | 4,29 | 4,11 | 3,93 | 4,28 | 4 | |||
| ❶ | Cooling capacity | kW | 15,2 | 18,6 | 26,1 | 30,2 | 33,1 | 38,9 | 44,4 | ||
| ❶ | E.E.R. | 4,56 | 4,41 | 4,7 | 4,44 | 4,12 | 4,64 | 4,3 | |||
| TCHITP-THHITP MODEL | 115 | 120 | 125 | 130 | 135 | 140 | 145 | ||||
| ❸ | Sound pressure | dB(A) | 51,5 | 53,5 | 56,5 | 58 | 58 | 58 | 59,5 | ||
| ❹ | Sound pressure | dB(A) | 48,5 | 50,5 | 53,5 | 55 | 55 | 55 | 56,5 | ||
| Scroll compressor/steps | no. | 1 inverter | 1 inverter | 1 inverter | 1 inverter | 1 inverter | 1 inverter | 1 inverter | |||
| Circuits | no. | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |||
| Electrical supply | V-ph-Hz | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | |||
| DIMENSIONS AND WEIGHTS | 115 | 120 | 125 | 130 | 135 | 140 | 145 | ||||
| L – Width | mm | 1265 | 1265 | 1265 | 1265 | 1265 | 1265 | 1265 | |||
| ❺ | H – Height | mm | 1350 | 1350 | 1350 | 1350 | 1350 | 1350 | 1350 | ||
| ❻ | H – Height | mm | 1460 | 1460 | 1460 | 1460 | 1460 | 1460 | 1460 | ||
| P – Depth | mm | 720 | 720 | 720 | 720 | 720 | 720 | 720 | |||
| ❼ | TCHITP weight | kg | 290 | 295 | 300 | 305 | 310 | 315 | 320 | ||
| ❼ | THHITP weight | kg | 295 | 300 | 305 | 310 | 315 | 320 | 325 | ||
| SEASONAL ENERGY PERFORMANCE | 115 | 120 | 125 | 130 | 135 | 140 | 145 | ||||
| TCHITP MODEL SEASONAL PERFORMANCE IN COOLING MODE | |||||||||||
| ① | Pdesignc (EN 14825) | kW | 16,6 | 20,1 | 28,2 | 32,5 | 35 | 40,6 | 45,9 | ||
| ① | SEER (EN 14825) | 6,62 | 6,72 | 7,24 | 7,29 | 6,89 | 7,13 | 6,92 | |||
| ② | ηs,c | % | 262 | 266 | 286 | 288 | 273 | 282 | 274 | ||
| THHITP MODEL SEASONAL PERFORMANCE IN HEATING MODE – Low temperature application 35°C | |||||||||||
| ③ | Pdesignh (EN 14825) | kW | 25 | 28 | 40 | 46 | 52 | 59 | 70 | ||
| ③ | SCOP (EN 14825) | 6,55 | 6,57 | 7,17 | 7,04 | 6,94 | 7,32 | 7,13 | |||
| ④ | ηs | % | 254 | 255 | 279 | 274 | 270 | 285 | 277 | ||
| ④ | Energy class | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | |||
| THHITP MODEL SEASONAL PERFORMANCE IN HEATING MODE – Medium temperature application 55°C | |||||||||||
| ③ | Pdesignh (EN 14825) | kW | 22 | 25 | 35 | 41 | 45 | 52 | 61 | ||
| ③ | SCOP (EN 14825) | 4,88 | 4,95 | 5,34 | 5,28 | 5,21 | 5,56 | 5,48 | |||
| ④ | ηs | % | 187 | 190 | 206 | 203 | 201 | 214 | 211 | ||
| ④ | Energy class | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | |||
- Data at the following conditions:
- ❶ Chilled water: 12/7°C – Condenser water: 30/35°C.
- ❷ Hot water: 40/45°C. – Evaporator water: 10/7℃.
- ❸ In open field (Q = 2) at 1 m from the unit (not Eurovent certified).
- ❹ In open field (Q = 2) at 1 m from the unit, with VE-VEX accessory (not Eurovent certified).
- ❺ Height referred to a unit with standard set up.
- ❻ Height referring to a unit with VE-VEX accessories.
- ❼ Weight refers to the unit empty with soundproofing.
- Performance according to EN 14511.
- ① Low temperature application (7°C)
- ② Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)
- ③ In Average climatic conditions
- ④ Seasonal energy efficiency: heating in Average climate (EU Regulations No.811/2013 and No.813/2013 – class between D and A+++)
Manuals
To view all the documents, log in to the reserved area
Technical notes
To view all the documents, log in to the reserved area
Documents
To view all the documents, log in to the reserved area
Images
Request information about this product
Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.