New
Web code: MFI07
CHILLERS HEAT PUMPS WATER-cooled CONDENSERLESS UNITS

MidiFLOW-PI

TCHITP-THHITP 115÷145
Cooling capacity 15,2÷45,9 kW
Heating capacity 17,6÷51,2 kW

Packaged water-cooled water chillers and reversible heat pumps on the cooling circuit with water-cooling system. Range with scroll hermetic compressors, DC inverter and R290 refrigerant gas.

Features

Key features


Efficient and eco-friendly range in R290

Applications with well water, water mains, geothermal probes or dry cooler

Ventilated enclosure or outdoor installation

Plug&Play unit with integrated hydraulic module

Temperature of the produced water up to 80°C

Integrated MASTER/SLAVE control


MidiFLOW-PI

Description

Construction features

• Compressor: hermetic rotary, scroll type with inverter actuation, complete with thermal protection and casing heater.
• Primary side (user) heat exchanger: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Disposal side heat exchanger (well, mains, geothermal probes or dry cooler): with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: made of galvanised and painted steel plate with polyester powder coating.
• Refrigerant leak detector.
• The unit is also complete with:
- electronic expansion valve;
- display of cooling circuit high and low pressure;
- Master/Slave control up to 4 units in parallel;
- clock board;
- 0-10V analogue signal for condensing/evaporating control performed by external device;
- automatic management of anti-legionella cycles.

Versions

• T - High efficiency version

Models

• TCHITP: unit designed for cooling only.
• THHITP: heat pump unit.

PUMP set up

Primary side (user): single electric pump, available with INVERTER operation.
Disposal side (well, mains, geothermal probes or dry cooler): single electric pump, available with INVERTER operation.

Factory fitted accessories

• Set-up for outdoor installation.
• Set-up for ventilated enclosure installation.
• Free-Cooling Management.
• Dry-Cooler Management.
• Setup for heat pump operation (only for TCHITP).
• Energy parameter measuring device.
• Forced limit of power consumption.
• Double safety valves.
• Silenced set up.
• Control of min/max power supply voltage.
• Low temperature water production.
• Digital input for double set-point.
• 4-20mA analogue signal for shifting set-point.
• Contacts for Smart Grid integration and photovoltaic system.
• Heat exchanger, electrical panel and electric pumps antifreeze heaters, if applicable.
• Interfaces for serial communication with other devices.
• Colour touch user keypad (remotely) with 7'' display.

Separately supplied accessories

• 3-way modulating condensing control valve.
• 2-way modulating condensing control valve.
• 3-way valve for the production of domestic hot water, managed by the adjustment.
• Outdoor air temperature probe for set-point compensation.
• Rubber anti-vibration mounts.
• Water filter.
• Air inlet fitting.
• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.

Technical data

TCHITP MODEL 115 120 125 130 135 140 145
Cooling capacity kW 16,6 20,1 28,2 32,5 35 40,6 45,9
Absorbed power kW 3,34 4,25 5,57 6,87 8,06 8,42 10,38
E.E.R. 4,97 4,73 5,06 4,73 4,34 4,82 4,42
THHITP MODEL 115 120 125 130 135 140 145
Heating capacity kW 17,6 21,7 30,1 35,1 39,2 44,7 51,2
Absorbed power kW 4,23 5,34 7,02 8,54 9,97 10,44 12,8
C.O.P. 4,16 4,06 4,29 4,11 3,93 4,28 4
Cooling capacity kW 15,2 18,6 26,1 30,2 33,1 38,9 44,4
E.E.R. 4,56 4,41 4,7 4,44 4,12 4,64 4,3
TCHITP-THHITP MODEL 115 120 125 130 135 140 145
Sound pressure dB(A) 51,5 53,5 56,5 58 58 58 59,5
Sound pressure dB(A) 48,5 50,5 53,5 55 55 55 56,5
Scroll compressor/steps no. 1 inverter 1 inverter 1 inverter 1 inverter 1 inverter 1 inverter 1 inverter
Circuits no. 1 1 1 1 1 1 1
Electrical supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50
DIMENSIONS AND WEIGHTS 115 120 125 130 135 140 145
L – Width mm 1265 1265 1265 1265 1265 1265 1265
H – Height mm 1350 1350 1350 1350 1350 1350 1350
H – Height mm 1460 1460 1460 1460 1460 1460 1460
P – Depth mm 720 720 720 720 720 720 720
TCHITP weight kg 290 295 300 305 310 315 320
THHITP weight kg 295 300 305 310 315 320 325
SEASONAL ENERGY PERFORMANCE 115 120 125 130 135 140 145
TCHITP MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 16,6 20,1 28,2 32,5 35 40,6 45,9
SEER  (EN 14825) 6,62 6,72 7,24 7,29 6,89 7,13 6,92
ηs,c % 262 266 286 288 273 282 274
THHITP MODEL SEASONAL PERFORMANCE IN HEATING MODE – Low temperature application 35°C
Pdesignh (EN 14825) kW 25 28 40 46 52 59 70
SCOP (EN 14825) 6,55 6,57 7,17 7,04 6,94 7,32 7,13
ηs % 254 255 279 274 270 285 277
Energy class A+++ A+++ A+++ A+++ A+++ A+++ A+++
THHITP MODEL SEASONAL PERFORMANCE IN HEATING MODE – Medium temperature application 55°C
Pdesignh (EN 14825) kW 22 25 35 41 45 52 61
SCOP (EN 14825) 4,88 4,95 5,34 5,28 5,21 5,56 5,48
ηs % 187 190 206 203 201 214 211
Energy class A+++ A+++ A+++ A+++ A+++ A+++ A+++
  • Data at the following conditions:
  • Chilled water: 12/7°C – Condenser water: 30/35°C.
  • Hot water: 40/45°C. – Evaporator water: 10/7℃.
  • In open field (Q = 2) at 1 m from the unit (not Eurovent certified).
  • In open field (Q = 2) at 1 m from the unit, with VE-VEX accessory (not Eurovent certified).
  • Height referred to a unit with standard set up.
  • Height referring to a unit with VE-VEX accessories.
  • Weight refers to the unit empty with soundproofing.
  • Performance according to EN 14511.
  • Low temperature application (7°C)
  • Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)
  • In Average climatic conditions
  • Seasonal energy efficiency: heating in Average climate (EU Regulations No.811/2013 and No.813/2013 – class between D and A+++)

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: TIF
Request information about this product









    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.