New
Web code: WKE45
CHILLERS HEAT PUMPS AIR-cooled AXIAL fans

WinPACK ECO HT65

THAEU 4120÷4190
Cooling capacity 103,6÷175,8 kW
Heating capacity 120,7÷197,4 kW

Packaged reversible air-cooled heat pumps with axial fans. Range with hermetic scroll compressors and R454B refrigerant.

Features

Key features


Efficient and eco-friendly range in R454B

Temperature of the produced water up to 65°C

Full optional unit

Integrated MASTER/SLAVE control

Partial heat recovery with pump and mixing valve


WinPACK ECO HT65

Description

Construction features

• Compressor: hermetic rotary, scroll type with steam injection, complete with thermal protection and casing heater.
• Water side heat exchanger: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Air side heat exchanger: featuring finned coil with copper pipes and aluminium fins.
• Fan: external rotor axial type electric fans equipped with internal thermal protection, accident protection grilles and proportional electronic device for continuous regulation of the rotation speed of the fans.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: load-bearing structure made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- compressor and fan circuit breaker switches;
- electronic expansion valve;
- display of cooling circuit high and low pressure;
- Master/Slave control up to 4 units in parallel;
- clock board;
- control of Variable Primary Flow (VPF_R).

Versions

• T - High efficiency version with oversized condensing section.
• Q - Super-silenced version complete with compressor technical compartment soundproofing, reduced speed fans and oversized condensing section.

Models

• THAETU: high efficiency heat pump unit.
• THAEQU: super silenced heat pump unit.

Factory fitted accessories

• PUMP with single or double electric pump, one of which automatic in standby. The electric pumps are available in the low or high head versions.
• TANK&PUMP with 440 - 700 litre (depending on the sizes) integrated buffer tank and single or double electric pump, complete with expansion tank, air vent valves, safety valve and water side pressure gauge.
• Inverter pump control for unit start-up.
• Desuperheater.
• Desuperheater with pump and mixing valve
• Condensing control with fans with EC motor.
• Condensing control with over-pressure fans (T version only)
• Power factor correction capacitors (cosφ > 0.94).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameter measuring device.
• Soft starter.
• Technical compressor compartment soundproofing.
• Compressor soundproof enclosures.
• Cooling circuit outlet valves.
• Refrigerant leak detector.
• Gas control and refrigerant leak detector (leak detector plus).
• Cooling circuit high and low pressure gauges.
• Double safety valves.
• Metal filters or coil protection nets.
• Copper/copper, pre-painted copper/aluminium or with hydrophilic treatment coils.
• Control of min/max power supply voltage and backup battery
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Contacts for Smart Grid integration and photovoltaic system.
• Evaporator antifreeze heater, electrical panel, buffer tank, electric pumps and heat exchangers for heat recovery if applicable, and base.
• Buffer tank integrative heaters.
• Low temperature water production.
• Interfaces for serial communication with other devices.
• Colour touch user keypad (fitted on the machine or remotely) with 7'' display.
• Anti-vibration mounts.

Separately supplied accessories

• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.

Technical data

THAETU-THAEQU MODEL 4120 4130 4140 4150 4170 4180 4190
Nominal heating capacity kW 122,6 136 145,4 154,7 178,3 187,7 197,4
Nominal heating capacity kW 120,7 133,8 142,7 151,7 175,3 184,3 193,7
C.O.P. 3,42 3,41 3,46 3,47 3,32 3,32 3,33
C.O.P. 3,47 3,46 3,5 3,51 3,42 3,41 3,41
Nominal cooling capacity kW 105,2 118,4 126,9 135,6 156 166,4 175,8
Nominal cooling capacity kW 103,6 116,7 124,7 132,9 153,4 164,4 172,1
E.E.R. 2,97 2,95 2,92 2,91 2,89 2,87 2,85
E.E.R. 2,82 2,8 2,74 2,7 2,83 2,81 2,75
Absorbed power kW 35,8 39,9 42 44,6 53,7 56,5 59,3
Absorbed power kW 34,8 38,7 40,8 43,2 51,3 54 56,8
THAETU-THAEQU MODEL 4120 4130 4140 4150 4170 4180 4190
THAETU sound pressure dB(A) 52 53 53 53 58 58 58
THAEQU sound pressure dB(A) 47 48 48 48 52 52 52
THAETU sound power dB(A) 84 85 85 85 90 90 90
THAEQU sound power dB(A) 79 80 80 80 84 84 84
Scroll compressors/steps n. 4/4 4/4 4/4 4/4 4/4 4/4 4/4
Circuits n. 2 2 2 2 2 2 2
Electrical supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
DIMENSIONS AND WEIGHTS 4120 4130 4140 4150 4170 4180 4190
L – Width mm 3660 3660 3660 3660 3700 3700 3700
H – Height mm 2000 2000 2000 2000 2030 2030 2030
P – Depth mm 1520 1520 1520 1520 2090 2090 2090
THAETU weight kg 1525 1530 1535 1540 1765 1770 1775
THAEQU weight kg 1575 1580 1585 1590 1815 1820 1825
SEASONAL ENERGY PERFORMANCE 4120 4130 4140 4150 4170 4180 4190
THAETU MODEL SEASONAL PERFORMANCE IN HEATING MODE – Low temperature application 35°C
Pdesignh (EN 14825) kW 96 107 114 122 141 148 156
SCOP (EN 14825) 4,21 4,27 4,33 4,36 4,14 4,2 4,22
ηs % 165 168 170 171 163 165 166
THAEQU MODEL SEASONAL PERFORMANCE IN HEATING MODE – Low temperature application 35°C
Pdesignh (EN 14825) kW 95 105 112 120 138 145 153
SCOP (EN 14825) 4,27 4,33 4,37 4,39 4,22 4,28 4,26
ηs % 168 170 172 173 166 168 167
THAETU MODEL SEASONAL PERFORMANCE IN HEATING MODE – Medium temperature application 55°C
Pdesignh (EN 14825) kW 105 117 124 133 153 161 170
SCOP (EN 14825) 3,49 3,54 3,57 3,6 3,48 3,51 3,53
ηs % 137 139 140 141 136 138 138
THAEQU MODEL SEASONAL PERFORMANCE IN HEATING MODE – Medium temperature application 55°C
Pdesignh (EN 14825) kW 104 115 123 131 150 158 167
SCOP (EN 14825) 3,54 3,59 3,61 3,63 3,53 3,55 3,56
ηs % 139 141 142 142 138 139 139
  • Data at the following conditions:
  • Air: 35°C – Water: 12/7°C
  • Air: 7°C, D.B. – 6°C W.B.- Water: 40/45°C.
  • In open field (Q = 2) at 10 m from the unit.
  • Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
  • Weight referred to the unit without load and not accessorised.
  • THAEQU super-silenced versions.
  • Performance according to EN 14511.
  • In Average climatic conditions.
  • Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/2013 and No.813/2013 – class between D and A+++)

Manuals

To view all the documents, log in to the reserved area